TECHNICAL DATA SHEET 

 GREEN UP COOL

 

 

 

Green Up Cool is a low-toxic, environmentally friendly corrosion concentrate inhibitor. Green Up Cool provides corrosion protection

in aqueous solutions for environmentally friendly corrosion concentrate product.
Based on Green Up technology, provides corrosion protection in aqueous solutions for all kinds of metals, including aluminum, iron,

copper and solder alloys, and offers excel-lent cavitation protection. It is effective against a wide range of microorganisms including

Gram positive/negative bacteria and fungi.

 

 PRODUCT BENEFITS

 - Easy maintenance

- No inhibitor testing is required

- Offers excellent pitting protection

- Effective long term corrosion protection for Aluminum brass, cast iron, steel,       

   solder , and copper.

- Improved system equipment life, like molds in the plastic industry and water  

   Pumps.

- No silicate dropout or gel formation during use or storage

- Excellent heat transfer

- Reduces hard water scale

- Superior protection in high operating temperature

- Protects against winter freeze up

 

DIRECTIONS FOR USE

 It is necessary to drain the existing coolant fluid contained in the coolant system before initially filling with a 7–10%

solution of Green Up Cool  in water. Depending on the condition of the system it may be necessary to thoroughly flush

the system to remove loose deposits and precipitates. Flushing is done preferably with a 5% solution of Green Up Cool

in fresh water. Using Green Up Cool for flushing will facilitate the removal of the deposits and provide corrosion protection

during and after the flushing operations. For new systems a simple flush will usually be sufficient to remove any cooling

fluid and the few deposits present. In older systems, hard water scale, corrosion deposits and precipitates from former

water treatment chemicals will not be removed by flushing only. Depending on the nature and amount of the deposits it

will be necessary to operate the equipment for some time to allow cleaning of the system by the standard 7–10% solution

of Green Up Cool.

 

Flushing Procedure for Cooling Systems in New equipment's

 

1. Completely drain the system.

2. Fill the system with 5% solution of Green Up Cool in fresh water (flushing fluid).

3. Run the equipment in fast idle speed or operate the engine in service for at least one  

    hour  after the flushing solution has been heated up to the normal cooling water  

    temperature.

4. Completely drain the system.

5. Check flushing fluid for deposits and precipitates.

6. Repeat step 2 to 5 if flushing fluid contains significant amounts of deposits or 

    precipitates.

    Always allow the engine to cool down before draining and filling the system.

7. Check cooling system filters (if present). Replace when required.

8. Fill the system with a 5–7% Green Up Cool solution in fresh water and maintain in  

    service between 5% and 7%.

 

 

 Flushing Procedure for  equipment's Cooling Systems in Service

 

1. Completely drain the system if possible and proceed as per -                                                                                     

   “flushing procedure for cooling systems in new equipment”.

2. If not possible, the system should be drained and filled concurrently to maintain the   

     system   water level But, reduce the content of the Nitrite treatment and remove as  

    many contaminants  as possible.

3. Fill the system with 5–10% solution of Green Up Cool in water.

4. Maintain the level in service between 5% and 10%.

    Green Up Cool will clean any deposits and sludge from the system. These  

    contaminants  should be systematically removed by partial draining and skimming  

    until the system   is fully  clean.

    Green Up Cool has very low depletion in service.  Suppletion is only to make toping  

    up for   losses due to cooling water leakage. Concentration should periodically be  

    checked by  means of fractometer.

 

Coolant Replacement Procedure

 

Success replacing the existing coolant in the plastic plants,

Care must be taken all the steps.

The all components for this project supplying by company.

The process consists of three steps.

Before beginning the process of replacing, the company will take an example of the existing coolant for checking the

status of existing material.

Step one –  Add scale dissolution in the existing water system

 (About 3-4% on the volume of water)

 Continue working for 24 hours

Step Two - Flush all water from the Cooling System then fill the cooling system with plain water.

Add rust cleaner (About 5% on the volume of water)

 Continue working for 24 hours

Step Three - Flush all cooling system.

 Fill ready coolant to the cooling system, and continue working normally.

Do not add any   material to the existing coolant.

Concentration of topping up product will be decided after examination of the fluid system.

All stages of the process will be accompanied by the company.

This service is free of charge.

 

Economics

The outstanding corrosion protection and low additive depletion results in less       maintenance and repair costs.

Health and Safety

For full Health and Safety data please refer to our specific MSDS Sheet, which is available upon request.

 

PHYSICAL PROPERTIES

  

Appearance:                                       -         CLEAR COLOURLESS  LIQUID
pH @ 5% DILUTION                           -             8-10
Density                                                -            1.02
Flash Point                                          -            None              

 

INGREDINT

 

This is a water-based product which contains a mixture of natural active components produced from plants and silicates.

None of the ingredients is produced from animals. All ingredients are fully biodegradable.

HELTH AND SAFETY

 

For full Health and Safety data please refer to our specific MSDS Sheet, which is available on Product list.                                               

                   

 PACK SIZES
 
 4lt, 18lt , 205lt barrels, 1000 litter canister 
                      

SHELF LIFE 

3 Years from date of manufacture
 

                                                                                                    

 

 